Environmental Analysis Multiparameter Photometer 115V
List Price: $453.00
Clarkson Price: $407.70
You Save: $45.30 (10 %)
Clarkson Catalog Number: HI83218-01
Manufacturer: Hanna Instruments
Manufacturer Catalog Number: HI83218-01
|
|
Clarkson HI83218-01
Environmental Analysis Multiparameter Photometer 115V
Hanna Instruments HI 83218-01
Description:
-
Light blocking cuvette holder
-
Backlit LCD
-
BEPS (Battery Error Prevention System) Alerts users in the event a low battery could effect readings
-
PC compatible via USB
-
Powered by rechargeable batteries or 12 VDC
-
Save and recall logged data at the touch of a button.
-
On-screen tutorial; with the tutorial function enabled, short guides relating to current operation are displayed.
-
HELP button; screen specific help can viewed at the touch of a button.
-
Method selection; users can easily select parameters via the Method button.
-
Setup button; instrument preferences such as backlight intensity and screen contrast can be changed via the setup button.
HI 83218 is a multiparameter bench meter that measures five parameters essential for
environmental analysis. It has three channels allowing for a wide range of tests.
The HI 83218 is designed to be simple to use and offer high accuracy measurements at a
low cost per test. In order to improve resolution and cover a wider range, there are dual
scales for ammonia, chromium and nitrite.
The optical system of HI 83218 is based on special subminiature tungsten lamps and narrow-
band interference filters to guarantee both high performance and reliable results.
HI 83218 has a powerful interactive user support that assists the user during the analysis
process. A full tutorial is available in the Setup Menu, and the Help Menu provides assistance
for every step in the measurement process. This meter can be connected to a PC via a USB
cable, where the data can be managed with optional HI 92000 Windows® compatible software.
Specifications:
|
Light Source
|
|
up to 5 tungsten lamps with different narrow band interference filters.
|
|
Light Detector
|
|
silicon photocell
|
|
Power Supply
|
|
external 12 VDC power adapter or built-in rechargeable battery
|
|
Environment
|
|
0 to 50°C (32 to 122°F); max 90% RH non-condensing
|
|
Dimensions
|
|
235 x 200 x 110 mm (9.2 x 7.87 x 4.33")
|
|
Weight
|
|
0.9 Kg (2 lbs.)
|
Multi Parameter Specifications
|
Parameter |
Range |
Method |
Reagent Code |
|
Ammonia HR
|
0.0 to 50.0 mg/L (ppm)
|
Nessler
|
HI 93733-01
|
|
Ammonia MR
|
0.00 to 10.00 mg/L (ppm)
|
Nessler
|
HI 93715-01
|
|
Chromium VI HR
|
0 to 1000 µg/L
|
Diphenylcarbohydrazide
|
HI 93723-01
|
|
Chromium VI LR
|
0 to 300 µg/L
|
Diphenylcarbohydrazide
|
HI 93749-01
|
|
Nitrate
|
0.0 to 30.0 mg/L (ppm)
|
Cadmium Reduction
|
HI 93728-01
|
|
Nitrite HR
|
0 to 150 mg/L (ppm)
|
Ferrous Sulfate
|
HI 93708-01
|
|
Nitrite LR
|
0.00 to 1.15 mg/L (ppm)
|
Diazotization
|
HI 93707-01
|
|
Phosphorus
|
0.0 to 15.0 mg/L (ppm)
|
Amino Acid
|
HI 93706-01
|
Accesories:
|
Solutions |
|
|
Cuvette Cleaning Solution
|
|
Accessories |
|
|
Dried Resin, 100 g
|
|
|
Active Carbon
|
|
|
Cuvette Cleaning Cloth
|
|
|
Glass Cuvette Set
|
|
|
Cap Set for Glass Cuvettes
|
|
|
Plastic Beaker Set, 100 mL
|
|
|
Glass Bottle and Stopper, 60 mL
|
|
|
Graduated Syringe Set (6), 1 mL
|
|
|
Syringe Tip Set
|
|
|
Glass Cylinder Set, 25 mL
|
|
|
Syringe, 60 mL
|
|
|
Graduated Syringe, 5 mL
|
|
|
Filter Assembly
|
|
|
Filter Set (25)
|
|
|
Demineralized Bottle, 230 mL
|
|
|
Windows® Compatible Software
|
|
|
USB Cable
|
|
Reagents & Standards |
|
|
Ammonia HR, Nessler Method (100 Tests)
|
|
|
Ammonia HR, Nessler Method (300 Tests)
|
|
|
Ammonia MR, Nessler Method (100 Tests)
|
|
|
Ammonia MR, Nessler Method (300 Tests)
|
|
|
Chromium VI HR, Diphenylcarbohydrazide Method (100 Tests)
|
|
|
Chromium VI HR, Diphenylcarbohydrazide Method (300 Tests)
|
|
|
Chromium VI LR, Diphenylcarbohydrazide Method (100 Tests)
|
|
|
Chromium VI LR, Diphenylcarbohydrazide Method (300 Tests)
|
|
|
Nitrate, Cadmium Reduction Method (100 Tests)
|
|
|
Nitrate, Cadmium Reduction Method (300 Tests)
|
|
|
Nitrite HR, ferrous sulphate method (100 Tests)
|
|
|
Nitrite HR, ferrous sulphate method (300 Tests)
|
|
|
Nitrite LR, diazotization method (100 Tests)
|
|
|
Nitrite LR, diazotization method (300 Tests)
|
|
|
Phosphorous, amino acid method (100 Tests)
|
|
|
Phosphorous, amino acid method (300 Tests)
|
Order Information:
HI 83218-01 (115V) and HI 83218-02 (230V) is supplied with sample cuvettes and caps (2 ea.),
cloth for wiping cuvettes (1), scissors, AC/DC power adapter, and instruction manual.