TURBIDITY & CHLORINE METER EPA COMPLIANT
|
Clarkson Catalog Number: HI93414
Manufacturer: Hanna Instruments
Manufacturer Catalog Number: HI93414
|
|
Clarkson HI93414
EPA Compliant Portable Turbidity and Chlorine Meter with Fast Tracker™
Hanna Instruments HI 93414
Description:
HANNA's HI 93414 Turbidity and Chlorine Meter utilizes an EPA compliant tungsten light source and state-of-the-art optical system that allows consistently reliable and accurate measurements for free and total chlorine as well as turbidity.
Users will appreciate the accuracy and sensitivity of this instrument, particularly at very low turbidity levels. To meet EPA reporting requirements these instruments have an EPA compliance reading mode. HI 93414 meets all EPA requirements with regards to the Standard Methods for Turbidity and Colorimetric Chlorine Measurements.
Turbidity is measured up to 1000 NTU and free and total chlorine measurements can be made in the 0.00 to 5.00 mg/L (ppm) range. Depending on the measured sample and required accuracy, users can select normal measurement, continuous measurement or signal averaging.
HI 93414 features the ability to use Hanna's (optional) Tag Identification System (TIS) which allows users to record the time and location of a specific measurement or series of measurements. Logged data can be downloaded to a PC through either USB or RS232 connections. Reliable performance of the instrument is validated using Hanna's exclusive Cal Check® system and our ready-made, NiST traceable chlorine standards.
For turbidity, a two, three or four-point calibration is available using pre-set or user defined standards. Frequent Calibration isn't necessary as the system compensates for variations in the intensity of the light source.
The instruments' Good Laboratory Practice functions allow traceability of calibration conditions including the time, date and last calibration points. At startup, the meter displays the percentage of remaining battery life. A 'low battery' warning message is also displayed on the LCD to avoid unexpected battery failure. This instrument is equipped with backlighting. The current date and time can be displayed on the LCD.
Specifications:
| Range |
Turbidity |
0.00 to 9.99 NTU;
10.0 to 99.9 NTU;
100 to 1000 NTU; |
| Range Selection |
Turbidity |
Automatic |
| Resolution |
Turbidity |
0.01 NTU from 0.00 to 9.99 NTU;
0.1 NTU from 10.0 to 99.9 NTU;
1 NTU from 100 to 1000 NTU; |
| Accuracy |
Turbidity |
±2% of reading plus 0.02 NTU |
| Range |
Free & Total Chlorine |
Free Cl2 0.00 to 5.00 mg/L;
Total Cl2 0.00 to 5.00 mg/L |
| Resolution |
Free & Total Chlorine |
0.01 mg/L from 0.00 to 3.50 mg/L;
0.10 mg/L above 3.50 mg/L; |
| Accuracy |
Free & Total Chlorine |
±0.02 mg/L @ 1.00 mg/L |
| Repeatability |
|
±1% of reading or 0.02 NTU, whichever is greater |
| Stray Light |
|
< 0.02 NTU |
| Typical EMC Deviation |
|
±0.05 NTU |
| Light Detection |
|
Silicon Photocell |
| Method |
Turbidity |
Ratio Nephelometric Method (90°), ratio of scattered and transmitted light; Adaptation of the USEPA Method 180.1 and Standard Method 2130 B. |
| Measuring mode |
|
Normal, Average, Continuous |
| Turbidity Standards |
|
1, 10, 100 and 750 NTU |
| Typical EMC Deviation |
|
±0.02 mg/L |
| Light Source |
|
Silicon photocell with 525 nm narrow band interference filters |
| Method |
Free & Total Chlorine |
Adaptation of the USEPA Method 330.5 and Standard Method 4500- Cl G. The reaction between chlorine and DPD reagent causes a pink tint in the sample. |
| Standards |
|
1 mg/L free chlorine, 1 mg/L total chlorine |
| Calibration |
Turbidity |
Two, three or four-point calibration |
| Calibration |
Free & Total Chlorine |
One-point calibration |
| Light Source |
|
Tungsten filament lamp |
| Lamp life |
|
Greater than 100,000 readings |
| Display |
|
60 x 90 mm LCD with back light |
| Logging Memory |
|
200 records |
| Serial Interface |
|
USB 1.1 or RS 232 |
| Environment |
|
To 50°C (122°F); max 95% RH non-condensing |
| Power Supply |
|
(4) 1.5V AA alkaline batteries or AC adapter |
| Auto Shut-off |
|
After 15 minutes of non-use |
| Dimensions |
|
224 x 87 x 77 mm (8.8 x 3.4 x 3.0”) |
| Weight |
|
512 g (18 oz.) |
Accessories:
| |
| HI 93414-11 |
CAL CHECK™ Calibration set for Free & Total Chlorine |
| HI 93703-50 |
Solution for Turbidity Calibration |
| |
| HI 93703-58 |
Silicon oil (15 mL) |
| HI 710005 |
Voltage adapter from 115V to 12 Vdc (USA plug) |
| HI 710006 |
Voltage adapter from 230V to 12 Vdc (European plug) |
| HI 710012 |
Voltage adapter from 240V to 12 Vdc (UK plug) |
| HI 710013 |
Voltage adapter from 230V to 12 Vdc (South Africa plug) |
| HI 710014 |
Voltage adapter from 230V to 12 Vdc (Australia plug) |
| HI 731318 |
Tissue for Wiping Cuvets |
| HI 731331 |
Glass Cuvet for HI 957xx Series Meters |
| HI 731335N |
Caps for cuvets |
| HI 740027P |
1.5V AA Battery |
| HI 92000 |
Windows® Compatible Software for Logging Instruments,
Photometers and Turbidity Meters |
| HI 920005 |
Tag Identification System (T.I.S.) |
| HI 920011 |
Cable for PC Connection, 5 to 9-pin |
| HI 920005 |
Tag Identification System (T.I.S.) |
| Reagents & Standards |
| HI 93701-01 |
Chlorine, free, DPD Method (100 Tests) |
| HI 93701-03 |
Chlorine, free, DPD Method (300 Tests) |
| HI 93711-01 |
Chlorine, Total, DPD Method (100 Tests) |
| HI 93711-03 |
Chlorine, Total, DPD Method (300 Tests) |
|
|
|