Please Note: ********** We are closed the last Monday in May for Memorial Day **************

Click on the "Contact Us" link below for our normal hours of operation.
Visit www.coronavirus.gov for Information on the Corona-virus disease (COVID-19) Pandemic.
If you do not understand these 3 words, google them: symptom, symptomatic and asymptomatic. Some of us were ignorant at Clarkson but not anymore.


How many young people under the age of 18 have died while having the Corona Virus in the state of California in the USA with a population of 39.5 million?
CDPH shows 104 as of May 9, 2023. This is 0.0002% of the California population. Have a health problem or over 80, yes it is dangerous but so is the Flu and Pneumonia.
Sweden with 10 million people never had any mask mandate and had the same results as the state of California! - - References: CDPH , Flu and Sweden

Browse by Manufacturer
Browse Categories

Solution Graphics
 
Search
Search our store

Echotherm IC20XR Digital Chilling/Heating Dry Bath

<< Previous in Dri-Baths Next in Dri-Baths >>
List Price: $1,670.00
Clarkson Price: $1,419.50
You Save: $250.50 (15 %)
Clarkson Catalog Number: IC20XR
Manufacturer: Torrey Pines Scientific
Supplier Catalog Number: IC20XR
Manufacturer Direct Shipment
Torrey Pines IC20, Torrey Pines IC20XT, Torrey Pines IC20XR
Clarkson IC20XR
Echotherm IC20XR Digital Chilling/Heating Dry Bath
Torrey Pines Scientific IC20XR
 

The completely solid-state EchoTherm IC20 Digital Electronic Chilling/Heating Dry Bath is compact, versatile, reliable and easy to use.

The chilling/heating surface is a 2.875” (7.3 cm) x 4.375” (11.1 cm) aluminum plate that is very flat for optimal contact with your sample. When unloaded, the plate surface will reach below 0°C in under two minutes. It will also heat to 37°C in approximately 3 minutes. This rate of chilling or heating may vary with the load on the plate. For instance, temperatures down to 4.0°C can be reached on a solid aluminum block as large as 4” (10.2 cm) x 3” (7.6 cm) x 6” (15.2 cm) in less than one hour. When insulated, these large blocks can be driven below 0°C. Temperature gradients from the center to the edge of any aluminum block mentioned will be less than 0.5°C at any temperature.

A sample cover is available for 96-well assay plates and aluminum blocks that will hold centrifuge tubes or other samples. These blocks are available as accessories.

Optional Models

  • XT Model: Chilling range expanded to -20°C without sample block. Recommended for holding samples at low temperatures without cycling.
  • XR Model: Dual Peltier modules for extra power, faster speeds between temperatures and expanded heating to 110°C without sample block. Recommended for larger loads and for cycling temperatures up and down.

Features

  • Energy-efficient Peltier design
  • Digital control to 1°C from -20–110°C w/o sample block
  • Control at ambient
  • Count down timer (up to 30 days) with alarm and user settable Auto-Off
  • RS232 I/O port for control and data collection
  • Built-in data logger
  • Electronic calibration. User can reset to any local standard
  • Small, compact size uses very little bench space
  • Field operation using cigarette lighter jack in any car or truck
  • 12-volt DC operation. Requires no agency safety approvals
  • External power supply provided is UL, CSA and CE approved
  • 12-month warranty
Applications Include
  • Maintaining 14°C for ligation reactions
  • Enzyme reactions and deactivations
  • Maintaining 17°C for storing oocytes
  • Hybridizations
  • PCR sample preparation
  • Chilling 15, 50, 250, and 500ml centrifuge tubes to 4C for storing reagents
  • Storing samples at ice bucket temperatures
  • Incubate samples in 96-well assay plates, or in aluminum blocks holding 0.2 ml, 0.5 ml or 1.5 ml centrifuge tubes
  • Storing enzymes or DNA libraries at your work station
  • Transporting samples from the field at exactly the right temperature
  • Chilling or heating samples in the field
  • Freezing and storing most any small sample at your workstation
  • General molecular biology applications
 
Specifications
Temperature
Range -10°C to 100°C (IC20)
-20C to 100C (IC20XT)
-10C to 110C (IC20XR) w/o sample block
Readability 1°C
Accuracy ±1°C
Stability ±1°C
Sensor Type Platinum RTD
Controller Type PID
Uniformity ±0.3°C
Timer
Range 00:01 to 30 days
Readability 1 second
Audible Alarm Yes, alarm sounds for 1 minute. Timer counts up until turned off.
Data Logger
Sample times 1 sec, 1 min or 5 minutes per data point
Capability 8110 data points
Electrical
Heater/Chiller Peltier, 50 watts (IC20)
100 watts (IC20XT and IC20XR)
Operating Voltages 100, 115 or 230 VAC, 50/60 Hz input to universal power supply.
12 VDC output to chiller/heater module.
Power Consumption 50 watts (IC20)
100 watts (IC20XT and IC20XR) maximum
Power Switch Yes, for 12 VDC into heater/chiller module
Chilling/Heating Module Dimensions
WXDXH
6.5X8.75X4.0in
(16.5X22.23X10.16cm)
Power Supply Dimensions
LXHXW
6.5X3.2X2.2in
(16.5X8.1X5.6cm)
Weight (power supply & chiller/heater module) 6.5 lbs
(2.9 kg)
 
Catalog Number Description Voltage
IC20 Digital Chill/Heat Plate w/power supply 90-265V
IC20XT Digital Chill/Heat Plate as above, extended chilling to -20C 90-265V
IC20XR * Digital Chill/Heat Plate with extra power & heating range 90-265V
 
Additional Information
Price List

Product Reviews

(0 Ratings, 0 Reviews)