UV-Vis Spectrophotometer T9DCS 120-230V 50/60Hz
List Price: $15,770.00
Clarkson Price: $14,193.00
You Save: $1,577.00 (10 %)
Clarkson Catalog Number: T110+
Manufacturer: Persee Analytics
Supplier Catalog Number: T110+
Manufacturer Direct Shipment
|
|
Clarkson T110+
UV-Vis Spectrophotometer T9DCS 120-230V 50/60Hz
Persee Analytics T110+
The T9/T10DCS Spectrophotometer incorporates dual monochromator technology making it well suited to even the most demanding of applications in all areas of UV-Visible Spectroscopy.
The optical design of both the T9DCS and T10DCS offer extremely low stray light characteristics (≤0.00004%T NaI,220 nm) which allows for an extensive photometric range (-8.0 – 8.0Abs). Measurements at deep ultra-violet wavelengths can also be achieved with use of Nitrogen purged optics.
The instrument can be optically configured to suit the needs of the sample by means of a continually adjustable slit for precise control of spectral resolution and beam size adjustment by means of an attenuating wheel.
Key Features
- True Double Beam Double monochromator Optics, and fully sealed to provide ultra-low stray light (0.00004%%T @220nm) and high photometric range (-8.0~8.0 Abs)
- 85– 900nm Wavelength range with Nitrogen purge
- Precise Wavelength accuracy is ensured by the integrated Mercury lamp for automatic correction
- Continuously selectable spectra bandwidth from 0.1-5nm
- Beam size continuously adjustable for variety of applications including ultra-volume cuvettes
- Large sample compartment suitable for all kinds of accessories, especially for 150mm integrating sphere
- Support WIFI communication in field operation
- The integrated Mercury Emissions Lamp with automatic correction function ensures precise wavelength accuracy
|
Specifications |
Model |
T9DCS |
T10DCS |
Optical System |
Double beam |
Double beam |
Scan Speed |
1000 nm/min 1500 nm/min location speed |
1000 nm/min 1500 nm/min location speed |
Wavelength Range |
185-900 nm |
185-900 nm |
Wavelength Accuracy |
±0.2 nm |
±0.2 nm |
Spectral Bandwidth |
±20 % (0.1 nm-5 nm continuously adjustable) |
±20 % (0.1 nm-5 nm continuously adjustable) |
Photometric Mode |
Transmittance,Absorbance, Enegy and Concentration
|
Transmittance,Absorbance, Enegy and Concentration
|
Photometric Range |
-6.0 Abs-6.0 Abs |
-8.0 Abs-8.0 Abs |
Photometric Accuracy |
±0.004 A@2.0 A ±0.003 A@1.0 A ±0.002 A@0.5 A ±0.3 % |
±0.004 A@2.0 A ±0.003 A@1.0 A ±0.002 A@0.5 A ±0.3 % |
Photometric Reproducibility |
≤0.002 A@2.0 A ≤0.0008 A/1.0 A ≤0.0004 A/0.5 A ≤0.1 % |
≤0.002 A@2.0 A ≤0.0008 A/1.0 A ≤0.0004 A/0.5 A ≤0.1 % |
Photometric Noise |
0 % Noise: ≤0.01 % 100 % Noise: ≤0.1 % |
0 % Noise: ≤0.01 % 100 % Noise: ≤0.1 % |
Baseline Flatness |
±0.0008 Abs |
±0.0005 Abs |
Baseline Stability |
0.1 %/hr |
0.1 %/hr |
Stray light |
≤0.0001 %T (NaI, 220 nm) ≤0.0001 %T (NaNO2, 360 nm) |
≤0.00004 %T (NaI, 220 nm) ≤0.00002 %T (NaNO2, 360 nm) |
Cell Holder |
Automatic 8 Cell Changer |
Automatic 8 Cell Changer |
Detector |
Photo multiplier tube |
Photo multiplier tube |
Light Source |
D2 lamp,Tungstern lamp,Mercury lamp for WL correction |
D2 lamp,Tungstern lamp,Mercury lamp for WL correction |
PC Interface |
RS232, USB, Wifi |
RS232, USB, Wifi |
Software Support |
UV Win |
UV Win |
Power Supply |
Switchable 120-230 VAC 50-60 Hz |
Switchable 120-230 VAC 50-60 Hz |
Weight |
136 lb |
136 lb |
Dimensions |
36 x 25 x 12 in |
36 x 25 x 12 in |
Catalog Number |
Model |
Description |
T110+ |
T9DCS |
Double monochromater spectrometer with fixed cell holder, wavelength range 185 - 900nm with a user defined bandpass from 0.1 - 5.0nm in increments of 0.1nm. Stray light lower than 0.0001%T. PC controlled by USB or RS232 cable or WIFI.
|
T112+ |
T10DCS |
Double monochromater spectrometer with fixed cell holder, wavelength range 185 - 900nm with a user defined bandpass from 0.1 - 5.0nm in increments of 0.1nm. Stray light lower than 0.00004%T. PC controlled by USB or RS232 cable or WIFI.
|
Additional Information T10DCS Comparison Data Sheet
|